| X-ray Generator | Type | Super high frequency generator with automatic exposure control | 
| Safety protect | With overload protection | 
| Frequency (output) | 460kHz | 
| Normal electric power | 50kW | 
| Exposure voltage kV | 40-150kV | 
| Exposure voltage precision | ±10% | 
| Exposure time | 1ms~8S | 
| Current | 10mA~640mA | 
| Current steps | 10mA, 12.5mA, 16mA, 20mA, 25mA, 32mA, 40mA, 50mA, 64mA, 80mA, 100mA, 125mA, 160mA, 200mA, 250mA, 320mA, 400mA, 500mA, 640mA | 
| Current time product | 0.1mAs ~ 640mAs | 
| Current time product steps | 0.1mAs; 0.125mAs; 0.16mAs; 0.2mAs; 0.25mAs; 0.32mAs; 0.4mAs; 0.5mAs; 0.64mAs; 0.8mAs; 1.0mAs; 1.25mAs; 1.6mAs; 2.0mAs; 2.5mAs; 3.2mAs; 4.0mAs; 5.0mAs; 6.4mAs; 8.0mAs; 10mAs; 12.5mAs; 16mAs; 20mAs; 25mAs; 32mAs; 40mAs; 50mAs; 64mAs; 80mAs; 100mAs; 125mAs; 160mAs; 200mAs; 250mAs; 320mAs; 400mAs; 500mAs; 640mAs | 
| Exposure mode | Manual/AEC (Automatic Exposure Control) | 
| ARP | ≥1000 position | 
| Power input | 380/400/415/440V~ 3ph 50/60Hz±1Hz Power: MAX: 90kVA Standby:1kVA | 
| Radiation dose display | DAP (optional) | 
| X-ray Tube Assembly | Anode | Rotating anode | 
| Target angle | 12° | 
| Min. focus input power | 22kW | 
| Max. focus input power | 54kW | 
| Input voltage | 40 ~ 150kV | 
| Max peak X-ray tube voltage | 150kV | 
| Max current range | 400/700 mA | 
| Nominal focal spot | dual focus 0.6 mm/1.2 mm | 
| Anode heat storage capacity | 163kJ/230kHU | 
| Housing heat storage capacity | 975kJ /1354 kHU | 
| Max housing heat dissipation rate | 196W(272 HU/sec) | 
| Max anode heat dissipation rate | 750W (1056HU/sec) | 
| Cooling method | Natural cooling | 
| Anode frequency | 50Hz/60Hz | 
| Anode rotation speed | 50Hz(2700r/min),60Hz(3200r/min) | 
| Inherent filtration | 1.3mmAl/75kV | 
| Weight | 16kg | 
| Collimator | Type | Manual collimator | 
| Beam shape | Rectangular | 
| Inherent filtration | 1.0mmAI/70kV | 
| Full field light localizer | Halogen light localizer | 
| Rotation degree | -45°~ 45° | 
| Additional filtration | 0.5, 1.0, 1.5mm AI | 
| Detector | Detector type | Digital flat panel detector (mobile wired) | 
| Material | Amorphous silicon (a-Si) semiconductor with cesium Iodide (CsI) scintillator | 
| Cooling method | Natural cooling | 
| DQE | >70% (0.1 lp/mm, RQA5) | 
| Pixel area (detector size) | 14 x 17.4inch / 35 x 43cm | 
| Pixel size | 143 μm | 
| Matrix size | 2448 x 2984 | 
| Dynamic range | 16 bit | 
| Spatial resolution | 3.7 lp/mm | 
| Imaging time of imaging system | 5s | 
| Preview time of imaging system | 2.5s | 
| Cycle time of imaging system | 6s | 
| Weight | 3.2kg | 
| Wire length | 9m | 
| Data transmission method | Ethernet | 
| Wall Stand | Type | Bucky stand | 
| Detector assembly vertical travel range | 1450mm (350mm ~ 1800mm), ±5% | 
| SID | 1000 ~ 2000mm | 
| Movement method | Manual | 
| Brake | Mechanical | 
| X-ray Tube Assembly Support System | Type | Floor rails system | 
| Control mode | Manual | 
| Tube assembly vertical travel range | manual:1240 mm (560mm~1800mm), ±5% | 
| Tube assembly transverse motion | manual: 1720mm, ±5% | 
| Movement method | Manual | 
| Tube vertical axis rotation angle | ≥360° | 
| Tube horizontal axis rotation angle | ≥360° | 
| Tube tilting angle | ≥37°(-20°~17°) | 
| Patient table | Type | Stationary floating table | 
| Table size | 2120mm×825mm×650mm (length , width, height) | 
| Transparency equivalent (mmAI) | ≤1.2mmAl/100kV | 
| Table panel floating range | trans:±130mm; logn:±450mm; (manual) | 
| Detector floating range | logn:±290mm; (manual) | 
| Load capacity | 200kg | 
| Brake | With footplate-brake on the wheels | 
| Chamber | Type | 3-field ionization chamber | 
| Inherent filtration | <0.7mmAl/75kV | 
| Voltage | 40kV~150kV | 
| Loading time | 0.5ms~10s | 
| Dose range | 0.174~174uGy | 
| Grid | Type | Fixed grid | 
| Focus | 1.0m+1.8m | 
| Grid ratio | 8:1 | 
| Line | 40L/cm | 
| Size | 470 x 450mm |